Pipeline Level Sensor
Pipeline Level Sensor

Applicable pipe diameter:? Φ6-13mm outside diameter

Applicable tube:? Transparent tube with wall thickness less than 1mm

Output mode:? NPN output/PNP output

Setting mode:? key self-learning

Output mode:? NPN.NO/NC


FGU-G613 series
https://item.taobao.com/item.htm?spm=a1z10.5-c-s.w4002-21983907666.10.73483c8bPjcdfq&id=601746321023
  • Characteristics
  • Specifications
  • Size
  • Wire
  • Download

Photoelectric principle, not easily affected by the measured medium;

Self-learning light-sensitive environment by pressing the key, simple and convenient operation;

No mechanical moving parts, high reliability;

Small size, can be installed at will;

Compliance with safety regulations, RoHS standard requirements requirements



Detection PrincipleNon contact photoelectric detection
?Model numberFGU-G613NFGU-G613P
Output type?NPN open collector output?PNP open collector output
Applicable pipeline materialTransparent/semi transparent catheter
Applicable pipeline outer diameterOuter diameter??6-13mm
Applicable pipeline wall thicknessWall thickness<1mm
Supply voltage?DC12-24±10% ripple wave(p-p)under 5%
?Operating mode?ON when blocking light ON when entering light Switching method
?Detected object?Liquid in the conduit (if the liquid is highly viscous or has suspended matter, it may not be detected)
?Action indicator light?Red status indicator; green status indicator
?Consumption current?Average value 30mA or less, maximum value 80mA or less
?Light sourceGaAs infrared light-emitting diode (940nm)
?Ambient illumination?Incandescent light - sunlight: 3000 Lux each or less
?Ambient temperature?Working: -10--+55 degree Celsius

?Storage: -25--65% Celsius (icing, condensation)

?Ambient humidity?When working:5-85%RH When storing:5-95%RH(condensation)
?Vibration (Durable)?10-500Hz? Single amplitude1.0mm
?Impact (Durability)?500m/s2?X,Y,Z?3 times in each direction
?Protective structure?IEC specification IP50
?Control output?Load power supply voltage DC12-24V, load current below 100mA;

Off power supply 0.5mA or less; residual voltage 0.8V or less (at 100mA load current)

Residual voltage 0.4V or less (at 40mA load current)

?Housing materialPolycarbonate
?Product size?25*16*17.2(length X width X hight)
?Connection mode?Lead wire lead line (standard wire length 2m)



Pipeline Level Sensor

Pipeline Level Sensor

FGU-G613說明書
FGU-G613說明書

Do you need help and service?

Full range of product types and wide applicability

We continuously study professional technology to accelerate the localization process of industrial sensors

Scale up across multiple industries, with over a thousand cumulative deployment cases

We look forward to your contact